Display Walk-In Freezer Repair

Display Walk-In Freezer Repair. I adjusted wiring on system to get the evaporator motors running. I checked system pressures; all pressures look normal. …
Soda Walk-In Cooler Repair

Soda Walk-In Cooler Repair. I replaced 1 evaporator fan motor as the old motor was locked. I cleared the drain line on the neighbor evaporator. …
Cold Shot Chiller Cleaning

Cold Shot Chiller Cleaning. I washed out the condenser coil, charged system with 6lbs of r410a as the sight glass was flashing near system set point. …
Stage 2 Compressor Grounded

Stage 2 Compressor Grounded causing the breaker to trip and installed a new stage 2 compressor. I replaced the liquid line drier and compressor contactor …
Cleaned AC RTU Condensers

Cleaned AC RTU Condensers. I cleared the drain lines, verified the evaporator is clean. I verified the blower belt is tight and if air filters …
Manitowoc Ice Machine Cleaning

Manitowoc Ice Machine Cleaning. I cleaned the internal water circuit components to insure full water flow. Washed out the condenser with coil cleaner. …
AC Scheduled Preventative Maintenance

AC Preventative Maintenance. I replaced indoor motor belt, cleared the drain line on all units, washed out the drain pans on all units, cleaned all …
Beverage Air Temp Cooler Repair

Beverage Air Temp Cooler Repair. I found trashing blocking the rotation on the far left evaporator fan motor; I removed the trash and verified the motors …
Traulsen 2 Door Freezer Repair

Traulsen 2 Door Freezer Repair. I found the intake and return air completely blocked with ice and the condenser coil extremely dirty with debris and oil. …
Ductless AC Repair

Ductless AC Repair. I found the breaker tripped. I reset the breaker and cleaned the condenser. Checked the refrigerant pressures. Operational pressures …