Hoshizaki Ice Machine Repair

Hoshizaki Ice Machine Repair

Hoshizaki Ice Machine Repair. I found the condenser completely clogged. Took apart the condenser fan motor plenums and brushed out the condenser …

Ice Cream Machine Repair

Ice Cream Machine Repair

Ice Cream Machine Repair. I found line power disconnected at a wire nut. Refastened line power and checked the refrigerant pressures. Full sight glass. …

Traulsen Freezer Repair

Traulsen Freezer Repair

Traulsen Freezer Repair. I found the main control board damaged; I replaced board with a raincoat universal control display. Verified that the heaters …

Daikin AC System Repair

Daikin AC System Repair

Daikin AC System Repair. I cleaned the condenser coil, cleaned the condenser coil on the mini split, recovered the refrigerant and changed out the …

Repaired Dining Room RTU

Repaired Dining Room RTU

Repaired Dining Room RTU. I found stage one and two cycling on and off on high head pressure. I clean the entire condenser coil with Viper coil cleaner. …

Repaired Damaged Run Capacitor

Repaired Damaged Run Capacitor

Repaired Damaged Run Capacitor. I replaced the run capacitor and cleaned the condenser coils for both walk in coolers. Verified the unit pumps down correctly

Repaired Everest Reach-In Cooler

Repaired Everest Reach-In Cooler

Repaired Everest Reach-In Cooler. I performed repair and confirmed both evaporator fan motors are now functional. No further action needed at this time …

Blue Air Reach In Freezer Repair

Blue Air Reach In Freezer Repair

Blue Air Reach In Freezer Repair. I found the drain line heater damaged. I acquired anew heater and replaced. Deiced the evaporator coil and drain line. …

Standex Condenser Repair

Standex Condenser Repair

Standex Condenser Repair. I installed a new clock inside the walk-in cooler and set it to control the thermostat and liquid line solenoid for proper pump down

Exhaust Hood Repair

Exhaust Hood Repair

Exhaust Hood Repair. I replaced the exhaust fan blower belt. No further action needed at this time. Confirmed the EF operates correctly …