Condenser Coil Clogged

Condenser Coil Clogged

Condenser Coil Clogged upon arrival. Washed out with viper coil cleaner. Checked the air handler drain pan. Checked the suction pressure; 125psi (normal). …

Cleaned All Condenser Coils

Cleaned All Condenser Coils

Cleaned All Condenser Coils and installed media filter on all units. Charged the T72 3 Door Cooler with 19oz of r134a. Picking up a refrigerant leak …

Schrader Valve Refrigerant Leak

Schrader Valve Refrigerant Leak

Schrader Valve Refrigerant Leak. I replaced the half inch Schrader valve, replaced the liquid line filter dryer and charged new 5lbs of r410a. …

Blue Air 2-Door Freezer Repair

Blue Air 2-Door Freezer Repair

Blue Air 2-Door Freezer Repair. I install New Compressor and Start Components. After installation, I monitored box temperature until it reached below 29*f. …

Trane AC Unit Repair

Trane AC Unit Repair

Trane AC Unit Repair. I found AC 2 drain pan full of water; I used a vacuum to clear. I cleared both units drain lines with CO2 and a vacuum on 6/3/25 …

Walk In Cooler Leak Repair

Walk In Cooler Leak Repair

Walk In Cooler Leak Repair. I found a refrigerant leak coming from the suction header on the evaporator. I replaced the Schrader valve and installed a new cap.

Hoshizaki Ice Machine Repair

Hoshizaki Ice Machine Repair

Hoshizaki Ice Machine Repair. I found the condenser completely clogged. Took apart the condenser fan motor plenums and brushed out the condenser …

Ice Cream Machine Repair

Ice Cream Machine Repair

Ice Cream Machine Repair. I found line power disconnected at a wire nut. Refastened line power and checked the refrigerant pressures. Full sight glass. …