Cold Plunge Chiller Repair. Performed system diagnostics and identified a refrigerant leak at the suction line. Repaired leak by properly soldering and sealing the suction line. Removed and replaced the liquid line filter dryer to ensure proper moisture and contaminant removal from the refrigeration system. Installed new compressor run capacitor due to faulty operation. Installed service tap, pressure tested, and pulled a deep vacuum to remove moisture and non-condensable from the system. System was then recharged with new R410A refrigerant. System was started and monitored for proper operation.