10212 Menchaca Rd Austin, TX 78748 United States
Tito · July 23, 2026 · 10212 Menchaca Rd Austin, TX 78748 United States

Completed commercial refrigeration repair on a True Refrigeration T-35 reach-in cooler after the customer reported the unit was no longer cooling properly. Upon arrival, the evaporator fan motor was operating, but the condenser fan motor and compressor were not running. A detailed electrical inspection revealed the power supply wiring feeding the condenser section had burned, causing a loss of power to the compressor and condenser fan assembly.
Repaired and reconnected the damaged electrical wiring, restoring power to the refrigeration system. During the inspection, the condenser coil was found to be heavily contaminated with oil, grease, and debris, severely restricting airflow and reducing the unit’s ability to reject heat efficiently. Performed a thorough condenser coil cleaning using commercial coil cleaner to restore proper airflow and improve refrigeration performance.
After completing the repairs, the reach-in cooler was restarted and monitored through normal operation. Verified proper compressor startup, condenser fan motor operation, and overall refrigeration performance. The unit successfully pulled the cabinet temperature below 40°F before departure, confirming that the refrigeration system was operating correctly.
At the time of departure, the True Refrigeration reach-in cooler was operating normally with proper compressor operation, condenser airflow, and cooling performance. Routine commercial refrigeration preventive maintenance, including condenser coil cleaning and electrical inspections, is recommended to improve energy efficiency, reduce compressor operating temperatures, and help prevent unexpected refrigeration failures in busy restaurant and bar environments.