Setpoint Services responded to diagnose the commercial back bar cooler after the customer reported excessive noise during operation. Inspection of the refrigeration system found the condenser fan motor bearings had failed, producing a loud grinding noise. Further inspection revealed the condenser coil was heavily impacted with dust and debris, severely restricting airflow across the condenser.
The failed condenser fan motor was replaced and the condenser coil was thoroughly cleaned using commercial condenser coil cleaner to restore proper airflow and heat rejection. Restricted airflow can cause elevated operating temperatures, increasing compressor stress and shortening condenser fan motor life.
After completing the repairs, the refrigeration system was restarted and tested. Verified proper condenser fan motor operation, restored airflow across the condenser coil, and confirmed the grinding noise had been eliminated. The back bar cooler was operating normally at the time of departure.