American BioTech Reach-in Repair

American BioTech Reach-in Repair. Replaced the filter-dryer. Inspected the system thoroughly for refrigerant leaks — none were found. Unit successfully held …
Cleaned Out Refrigerant Lines

Cleaned Out Refrigerant Lines with RX 11 as the old compressor created acid and sent it through the refrigerant lines. Replaced Compressor …
Micro Matic Repair

Micro Matic Repair. Thoroughly washed condenser coil using Viper coil cleaner. Coil appeared not to have been cleaned in 7 years. …
True Manufacturing Refrigeration Repair

True Manufacturing Refrigeration Repair. Replaced evaporator fan motors and room temperature sensor. I replaced the provided components and verified operation.
Turbo Air Refrigeration Leak

Turbo Air Refrigeration Leak. Found a small refrigerant leak located on the discharge line service valve. Stopped leak same day with no parts. …
Turbo Air System Repair

Turbo Air System Repair. Upon inspection, the sight glass was flashing, indicating possible low refrigerant or restriction in the liquid line. …
Heatcraft Refrigeration Refrigerant Leak

Heatcraft Refrigeration Refrigerant Leak on the return bend of the evaporator coil, located on the left side of the evaporator. Performed a system pump-down …
Replaced Broken Condenser Fan Blade

Replaced Broken Condenser Fan Blade. I attached to motor model D7747. Verified proper rotation and operation after replacement. Unit is running normally …
Exhaust Fan Motor Replacement

Exhaust Fan Motor Replacement. I Provided labor, materials, and equipment necessary to replace the existing exhaust fan motor and pulleys, …
Pizza Table Repaired Refrigerant Leak

Pizza Table Repaired Refrigerant Leak located on pizza prep table Equipment. A refrigerant leak was found on the low-side access fitting. The leak was repaired