Penguin Chiller Repair

Penguin Chiller Repair. I replaced the heat exchanger. I pulled a system vacuum and charged with 1 lb. and 5 oz of r410a on 5/4/25 in Austin Texas.
Two Door Prep Table Repair

2 Door Prep Table Repair. I found system low on charge upon arrival. I installed suction and discharge line taps, pulled a vacuum and charged 3oz of r290. …
Repaired a Damaged Controller

Repaired a Damaged Controller. The compressor will not turn off when in defrost or when the power button is pressed. I replace the Control Board …
True Reach In Freezer Repair

True Reach In Freezer Repair. I Found the condenser fan motor faulty. I acquired fan motor and run capacitor same day and replaced them. I cleaned the condenser
Goodman Split Air Repair

Goodman Split Air Repair. Washed out the condenser coil, charged system with 6lbs of r22, leak checked the entire system but unable to locate a leak …
Refrigeration PM

Refrigeration PM. Cleaned all the plug-in cooler and freezer condenser coils. Cleaned the condensers for both walk in coolers. No issues found at this time …
True 2 Door Freezer Repair

True 2 Door Freezer Repair. I installed anew compressor, installed a new liquid line drier, pulled a system vacuum and charged with new r404a refrigerant. …
Manitowoc Ice Machine Pump Repair

Manitowoc Ice Machine Repair. I Found the water pump faulty. I picked up a new pump and replaced the same day. Cleaned out the condenser coil and monitor …
Rheem Split AC Repair

Rheem Split AC Repair. I found the system shut off due to the drain line completely clogged. I cleared the drain with dry nitrogen and bleach. …
Atosa Reach-In Freezer Maintenance

Atosa Reach-In Freezer Maintenance. Cleaned all condensers for the self-contained units including the ice machine and walk in cooler. Ran cleaner and sanitizer