Full Cleaning Manitowoc Ice Machine

Full Cleaning Manitowoc Ice Machine. Completely removed and cleaned all removable parts using hand cleaner and sanitizer solution. Cleaned and sanitized …
Walk-In Freezer Leak

Walk-In Freezer Leak. Added 2 lbs. of R-404A to system. After refrigerant addition, system discharge pressure increased to 225 PSI. …
Cleaned and Serviced Ice Machine

Cleaned and Serviced Ice Machine head system, including evaporator section and condenser coil. Diagnosed T4 fault condition and found evaporator outlet …
Remove and Replace Failed Electronic

Remove and Replace Failed Electronic temperature controller. Existing controller has a damaged internal fan switch causing evaporator fan motors to not operate
Manitowoc Ice Machine Temporary Repair

Manitowoc Ice Machine Repair. Inspected ice machine due to unit shutting down during operation. Found condenser fan motor not running, …
Manitowoc Maintenance

Manitowoc maintenance. Installed a LuminIce unit on the ice machine. Clean condenser using Viper coil cleaner. Clean all removable water circuit components, …
Repaired Refrigerant Leak on Evaporator

Repaired Refrigerant Leak on Evaporator outlet to the prep table. Pulled a system vacuum and charged system with 5oz of r290 refrigerant. Monitored system …
Replaced Compressor Start Components

Replaced compressor start components, including capacitor and associated wiring as needed. Verified proper operation of the system after replacement. …
Replaced the Heater Kit

Replaced the Heater Kit located in the air handler. Installed customer-provided thermostat and verified proper wiring and operation. …
Randell Prep Table Repair

Randell Prep Table Repair. I found one of the two wires going to the main ON/OFF switch burnt and disconnected. Repaired and reconnected the damaged wire, …