True Reach In Freezer Repair
True Reach In Freezer Repair. I Found the condenser fan motor faulty. I acquired fan motor and run capacitor same day and replaced them. I…
Read More »
Goodman Split Air Repair
Goodman Split Air Repair. Washed out the condenser coil, charged system with 6lbs of r22, leak checked the entire system but unable to locate a…
Read More »
Refrigeration PM
Refrigeration PM. Cleaned all the plug-in cooler and freezer condenser coils. Cleaned the condensers for both walk in coolers. No issues found at this time…
Read More »
True 2 Door Freezer Repair
True 2 Door Freezer Repair. I installed anew compressor, installed a new liquid line drier, pulled a system vacuum and charged with new r404a refrigerant.…
Read More »
Manitowoc Ice Machine Pump Repair
Manitowoc Ice Machine Repair. I Found the water pump faulty. I picked up a new pump and replaced the same day. Cleaned out the condenser…
Read More »
Rheem Split AC Repair
Rheem Split AC Repair. I found the system shut off due to the drain line completely clogged. I cleared the drain with dry nitrogen and…
Read More »
Atosa Reach-In Freezer Maintenance
Atosa Reach-In Freezer Maintenance. Cleaned all condensers for the self-contained units including the ice machine and walk in cooler. Ran cleaner and sanitizer
Read More »
Replaced 3 Evaporator Heaters
Replaced 3 Evaporator Heaters. I the heater evaporators after de icing the evaporator coil. All heaters pulling a normal 3amps on each side upon departure.…
Read More »
Cleaned and Sanitized Ice Machine
Cleaned and Sanitized Ice Machine. I cleaned the head and ice bin. Washed out the condenser coil with viper coil cleaner. No further action needed…
Read More »