Condenser Coil Completely Clogged
Condenser Coil Completely Clogged with debris. Took apart the condenser frame and washed out the coil. Replaced 4 customer provided supply air filters. Swapped zone 2 wires to run 24…
Read More about Condenser Coil Completely Clogged »
Repaired Refrigerant Leak
Repaired Refrigerant Leak with solder located on the right side of the evaporator; evaporator suction outlet. Pulled a system vacuum and charged system with 5oz of r290 refrigerant. Monitored system…
Read More about Repaired Refrigerant Leak »
Cleaned and Sanitized the Ice Machine
Cleaned and Sanitized the Ice Machine. Cleaned and sanitized the ice machine head. Washed out condenser with viper coil cleaner. Monitored machine until 1 batch of ice harvested. No further…
Read More about Cleaned and Sanitized the Ice Machine »
Replace Defrost and Room Temp Sensor
Replace Defrost and Room Temp Sensor. Replaced compressor power relay no charge. No further action needed at this time in Georgetown Texas.
Read More about Replace Defrost and Room Temp Sensor »
Installed New Liquid Line Filter Dryer
Installed New Liquid Line Filter Dryer along with a suction side valve tap. Pulled the deep vacuum and performed a standing vacuum test; passed test. Charge system with nitrogen and…
Read More about Installed New Liquid Line Filter Dryer »
Washed Out the Condenser Coil
Washed out the condenser coil with viper coil cleaner. Replaced both capacitors. Charged system with 1.5lbs of r410a. Brushed out the evaporator coil. Checked for any refrigerant leaks. No leaks…
Read More about Washed Out the Condenser Coil »
Found Evaporator Completely Iced Over
Found evaporator completely iced over. The metering device was incorrectly mounted. Repaired on the spot. Thermostat was set to turn the compressor off 33*f/on 37*f. Adjusted thermostat to turn off…
Read More about Found Evaporator Completely Iced Over »
Washed Out Both Condenser Coils
Washed out both condenser coils with viper coil cleaner. Replaced both dual run capacitors. Brushed debris from both evaporators on 9/12/24 in Austin Texas.
Read More about Washed Out Both Condenser Coils »
Replaced Heat Exchanger with New Gaskets
Replaced Heat Exchanger with new gaskets and replaced the thermostat as well. Verified the gas heat functions correctly and turns off upon set point on 1/31/25 in Elgin Texas.
Read More about Replaced Heat Exchanger with New Gaskets »