Repaired Atosa 2 Door Prep Table
Repaired Atosa 2 Door Prep Table Cooler. I Cleaned the condenser coil. Removed piercing valve taps and installed a high and low copper tap. I…
Read More »
Condenser Coil Completely Clogged
Condenser Coil Completely Clogged with debris. Took apart the condenser frame and washed out the coil. Replaced 4 customer provided supply air filters. Swapped zone…
Read More »
Repaired Refrigerant Leak
Repaired Refrigerant Leak with solder located on the right side of the evaporator; evaporator suction outlet. Pulled a system vacuum and charged system with 5oz…
Read More »
Cleaned and Sanitized the Ice Machine
Cleaned and Sanitized the Ice Machine. Cleaned and sanitized the ice machine head. Washed out condenser with viper coil cleaner. Monitored machine until 1 batch…
Read More »
Replace Defrost and Room Temp Sensor
Replace Defrost and Room Temp Sensor. Replaced compressor power relay no charge. No further action needed at this time in Georgetown Texas.
Read More »
Installed New Liquid Line Filter Dryer
Installed New Liquid Line Filter Dryer along with a suction side valve tap. Pulled the deep vacuum and performed a standing vacuum test; passed test.…
Read More »
Washed Out the Condenser Coil
Washed out the condenser coil with viper coil cleaner. Replaced both capacitors. Charged system with 1.5lbs of r410a. Brushed out the evaporator coil. Checked for…
Read More »
Found Evaporator Completely Iced Over
Found evaporator completely iced over. The metering device was incorrectly mounted. Repaired on the spot. Thermostat was set to turn the compressor off 33*f/on 37*f.…
Read More »
Washed Out Both Condenser Coils
Washed out both condenser coils with viper coil cleaner. Replaced both dual run capacitors. Brushed debris from both evaporators on 9/12/24 in Austin Texas.
Read More »